| Model |
High Spin (RPM) |
G-Force |
| CSL35 |
910 |
399 |
|
NX40 |
700 |
209 |
| NX60 |
700 |
222 |
|
CSL60 |
810 |
297 |
|
NX100 |
600 |
183 |
|
CSL110 |
750
|
310 |
| NX140 |
575
| 197 |
|
CSL175 |
700
| 315 |
| CSL225 |
650 |
293 |
| CSL350 |
625 |
324 |
| CSL450 |
650 |
378 |
| DW100 |
680 |
260 |
| DW150 |
650 |
290 |
| DW200 |
625 |
280 |
| DW300 |
600 |
295 |
| DW400 |
600 |
295 |
| DW100PT |
625 |
232 |
| DW150PT |
590 |
237 |
| DW200PT |
580 |
229 |
| DW300PT |
550 |
223 |
| DW400PT |
540 |
248 |
| NX, CSL and DW models feature inverter
with single motor drive. Extract speeds are field programmable
in (1) RPM increments the DynaTrol HMi touch screen control. |
| |
| Boiler HP
Chart |
This technical
data is based on the following criteria:
cycle time = 45
minutes
incoming water temperature = 60oF
desired hot water temperature = 160oF
amount of hot water = 60% of water in total cycle
|
Model |
Boiler Horsepower |
| CSL35 |
1.2 |
| NX40 |
1.2 |
| NX60 |
1.6 |
|
CSL60 |
1.6 |
|
NX100 |
2.8 |
|
CSL110 |
2.9 |
| NX140 |
4.5 |
| CSL175 |
7.0 |
| CSL225 |
9.5 |
| CSL350 |
11 |
| CSL450 |
15 |
| DW100 |
3.4 |
| DW150 |
6.7 |
| DW200 |
9.2 |
| DW300 |
10.8 |
| DW400 |
13.1 |
BHP
required calculated on a per unit basis.
Formula used: (Total number of
gallons to be heated) x (8.33) x (temperature difference in Fahrenheit
between incoming cold water and desired temperature of hot water) = BTU
required. BTU divided by 35,500 = BHP
|
| Water Graduation Chart |
|
Water Level |
NX40 |
NX60 |
NX100 |
NX140 |
| Low |
4 gal. |
8 gal. |
9 gal. |
12
gal. |
| Medium Low |
8 |
13 |
16 |
26 |
| Medium |
13 |
19 |
24 |
35 |
| Medium High |
18 |
30 |
40 |
46 |
| High |
23 |
35 |
50 |
65 |
|
Water Level |
CSL35 |
CSL60 |
CSL110 |
CSL175 |
CSL225 |
CSL350 |
CSL450 |
| Low |
4 gal. |
8 gal. |
9 gal. |
11 gal. |
32 gal. |
32 gal. |
32 gal. |
| Medium Low |
8 |
13 |
16 |
24 |
59 |
59 |
59 |
| Medium |
13 |
19 |
24 |
33 |
86 |
86 |
86 |
| Medium High |
18 |
30 |
40 |
43 |
118 |
118 |
118 |
| High |
23 |
35 |
50 |
62 |
152 |
152 |
152 |
|
Water Level |
DW100 |
DW150 |
DW200 |
DW300 |
DW400 |
| Low |
16 gal. |
19 gal. |
21 gal. |
29 gal. |
35 gal. |
| Medium Low |
30 |
41 |
42 |
58 |
65 |
| Medium |
38 |
53 |
54 |
75 |
83 |
| Medium High |
59 |
77 |
82 |
112 |
123 |
| High |
80 |
104 |
113 |
155 |
165 |
|
| Average
Cycle Water Consumption Chart |
|
NX40 |
NX60 |
NX100 |
NX140 |
| 76 gal. |
115 gal. |
190 gal. |
265
gal. |
|
CSL35 |
CSL60 |
CSL110 |
CSL175 |
CSL225 |
CSL350 |
CSL450 |
|
67 gal. |
115 gal. |
210 gal. |
330 gal. |
425 gal. |
665 gal. |
855 gal. |
|
DW100 |
DW150 |
DW200 |
DW300 |
DW400 |
|
190 gal. |
285 gal. |
380 gal. |
570 gal. |
760 gal. |
|